The Impact of Wind Power and Load Power Fluctuations on Energy Storage Sizing
Вантажиться...
Дата
2023
Автори
Науковий керівник
Назва журналу
Номер ISSN
Назва тому
Видавець
КПІ ім. Ігоря Сікорського
Анотація
The study presents a method of taking into account the impact of wind power and load power fluctuations on the energy storage sizing, comprised of batteries of identical capacity. To account the impact, two methods of calculating the difference between wind power generation and load consumption were presented over some time interval: 1st and 2nd order difference methods. Each of the methods can be parameterized and non-parameterized method with and without taking into account parameters respectively, where the parameters are: discharge current, required discharge duration, depth of discharge, battery capacity, Peukert’s constant, discharge time from 100% capacity, ambient temperature and wind power prediction error. Using the parameterized method compared allows to refine the value of the number of batteries. Using the 2nd order difference method compared to the 1st order difference method can significantly reduce the required number of batteries.
Опис
Ключові слова
energy storage system, battery, optimal sizing, wind, load, predictive energy balancing, система зберігання енергії, акумулятор, енергоємність, вітер, навантаження, прогнозне балансування енергії
Бібліографічний опис
Yaremenko, M. K. The Impact of Wind Power and Load Power Fluctuations on Energy Storage Sizing / M. K. Yaremenko, K. S. Klen // Мікросистеми, Електроніка та Акустика : науково-технічний журнал. – 2023. – Т. 28, № 3(125). – С. 290932.1-290932.9. – Бібліогр.: 32 назв.