Deformation indicators of metacarpal bones fracture fixation
dc.contributor.author | Shidlovskiy, M. S. | |
dc.contributor.author | Dyman, M. M. | |
dc.contributor.author | Tsygankov, M. A. | |
dc.date.accessioned | 2020-05-11T08:25:00Z | |
dc.date.available | 2020-05-11T08:25:00Z | |
dc.date.issued | 2019 | |
dc.description.abstracten | Functional reliability of fixative-bone means was studied for various types of metacarpal fractures depending on the type of fixator and its location. The stiffness characteristics of fracture fixation systems with titanium miniplates were studied, an analysis was performed of the surgical treatment of patients with metacarpal fractures, in which osteosynthesis with needles and external fixation rod apparatus was used, with static and cyclic modes of action of external loads. When transferring a compressive force to a fragment, the type of fixing means significantly influences the deformation of the osteosynthesis system at all levels of stress; for the most of the measured characteristics, rod devices with external fixation and titanium miniplates of various designs are preferable. | uk |
dc.description.abstractru | В статье исследована функциональная надежность средств фиксатор-кость при разных типах переломов пястных костей в зависимости от типа фиксатора и его расположения. Изучены характеристики жесткости систем фиксации переломов с титановыми минипластинами, был проведен анализ оперативного лечения больных с переломами пястных костей, при котором применялся металоостеосинтез спицами и стержневой аппарат внешней фиксации, при статичных и циклических режимах действия внешних нагрузок. При передаче сжимающего усилия на обломок тип фиксирующих средств существенно влияет на деформации системы остеосинтеза при всех уровнях нагрузки; за большинством измеренных характеристик преимущество имеют стержневые аппараты внешней фиксации и титановые минипластины разных конструкций. | uk |
dc.description.abstractuk | Досліджено функціональну надійність засобів фіксатор-кістка при різних типах переломів п’ясних кісток в залежності від типу фіксатора та його розташування. Вивчені характеристики жорсткості систем фіксації переломів з титановими мініпластинами, був проведений аналіз оперативного лікування хворих з переломами п’ясних кісток, при якому застосовувався металоостеосинтез шпицями та стрижневий апарат зовнішньої фіксації, при статичних та циклічних режимах дії зовнішніх навантажень. При передачі стискаючого зусилля на відламок тип фіксуючих засобів суттєво впливає на деформації системи остеосинтезу при всіх рівнях навантаження; за більшістю виміряних характеристик перевагу мають стрижневі апарати зовнішньої фіксації та титанові мініпластини різних конструкцій. | uk |
dc.format.pagerange | P. 78-84 | uk |
dc.identifier.citation | Shidlovskiy, M. S. Deformation indicators of metacarpal bones fracture fixation / M. S. Shidlovskiy, M. M. Dyman, M. A. Tsygankov // Mechanics and Advanced Technologies. – 2019. – №1 (85). – P. 78-84. | uk |
dc.identifier.doi | http://dx.doi.org/10.20535/2521-1943.2019.85.157907 | |
dc.identifier.uri | https://ela.kpi.ua/handle/123456789/33363 | |
dc.language.iso | en | uk |
dc.publisher | Igor Sikorsky Kyiv Polytechnic Institute | uk |
dc.publisher.place | Kyiv | uk |
dc.source | Mechanics and Advanced Technologies, 2019, №1 (85) | uk |
dc.subject | остеосинтез | uk |
dc.subject | металоостеосинтез | uk |
dc.subject | підголівчатий перелом п’ясних кісток | uk |
dc.subject | зміщення уламків | uk |
dc.subject | фіксація переломів | uk |
dc.subject | жорсткість фіксації переломів | uk |
dc.subject | міцність фіксації переломів | uk |
dc.subject | п’ясна кістка | uk |
dc.subject | гвинти | uk |
dc.subject | спиці | uk |
dc.subject | мініпластина | uk |
dc.subject | стрижневий апарат зовнішньої фіксації | uk |
dc.subject | osteosynthesis | uk |
dc.subject | fracture of metacarpal bones | uk |
dc.subject | displacement of fragments | uk |
dc.subject | fixation fractures | uk |
dc.subject | the stiffness of fixation of fractures | uk |
dc.subject | strength of fixation of fractures | uk |
dc.subject | metacarpal bones | uk |
dc.subject | screws | uk |
dc.subject | needles | uk |
dc.subject | miniplates | uk |
dc.subject | rod apparatus external fixation | uk |
dc.subject | остеосинтез | uk |
dc.subject | металоостеосинтез | uk |
dc.subject | подголовчатый перелом пястных костей | uk |
dc.subject | смещения обломков | uk |
dc.subject | фиксация переломов | uk |
dc.subject | жесткость фиксации переломов | uk |
dc.subject | прочность фиксации переломов | uk |
dc.subject | пястная кость | uk |
dc.subject | винты | uk |
dc.subject | спицы | uk |
dc.subject | минипластина стержневой аппарат внешней фиксации | uk |
dc.subject.udc | 616.879.235-089 | uk |
dc.title | Deformation indicators of metacarpal bones fracture fixation | uk |
dc.type | Article | uk |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- madt_2019-1_10.pdf
- Розмір:
- 1.32 MB
- Формат:
- Adobe Portable Document Format
- Опис:
Ліцензійна угода
1 - 1 з 1
Ескіз недоступний
- Назва:
- license.txt
- Розмір:
- 9.06 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: